Data Centers

We specialize in shaving months of on-site time off your data center construction schedule by fabricating your custom building at our campus. Nearing a half million square feet of data center exterior panel experience, KLOVER is the proven choice for your next project.

Contact Our Team Today!
Download Data Center Flyer

Speed to Revenue

 How much is an additional 5.5 months of Data Center Uptime worth to your client?

Our average data centers currently consist of 55,000 square feet of exterior panels. We typically erect them 60 feet above the ground in only 10 days. Compare that to the 6 months of site time required to frame using traditional methods.

Every panel and data center product is custom manufactured for your project and placed quickly and safely by a specialized rigging crew with thousands of hours of experience. To increase field schedule efficiency, KLOVER can often include an air vapor barrier to provide a rapid “dry-in” condition on the panel with field closed seams. This allows for timely completion of other critical trade work.

Schedule Certainty

As data center contractors, we lead the coordination of all inputs during the critical design phase. You can follow the progress of your job on our detailed milestone schedule of the design and fabrication process with milestones for every step leading up to your installation date.

Since 2009, KLOVER has designed, manufactured, and installed an average of 825,000 square feet of prefabricated wall panels annually. In 2024 alone, we supplied 225,000 square feet of data center panels. KLOVER understands the unique scheduling requirements of data center construction.

Complete your project faster, safer, greener, and smoother.

Our experienced tradesmen, technical team, and leadership staff won’t rest until your project is completed on time with the quality you expect.

Safer By Design

KLOVER’s prefabrication methods safely reduce work hours on site by up to 75%.

Reduced crew-hours are particularly important for vertical data center projects due to the amount of work performed at up to 100 feet above grade. Our data center builders have extensive experience working safely at heights.

Lower Environmental Impact

On a 2024 data center project, KLOVER reduced fuel consumption by 3,600 gallons by simplifying the delivery stream to the jobsite and reducing the use of equipment on site. By fabricating and cutting studs to custom lengths from coil material, we saved 3,000 feet of steel that would have been wasted using traditional methods.